Fire Exit Hardware

Understand panic bars: the 3 actions that make emergency exit instant

Fred Duncombe Editorial Team 10 min read · Updated
Understand panic bars: the 3 actions that make emergency exit instantSave
Share

A panic bar is a horizontal push mechanism fitted across the inside of a fire exit door, designed to release the latch when pressure is applied from any point along its length. It allows people to leave a building quickly without fumbling for a handle or key, even in darkness or when carrying something. This guide explains how the device works, where regulations require it, and how to choose the right grade for your building.

Recognise the three ways a panic bar releases

Panic hardware responds to three distinct actions, and the standard you buy will specify which one it meets. Push-pad bars need downward pressure on a wide horizontal pad; you lean into it with your hand, forearm or body weight, and the latch retracts. Touch bars release when any part of the bar is touched or pushed, making them faster in a genuine emergency where coordination is difficult. Crash bars – often used interchangeably with panic bars in conversation – typically describe the horizontal rail type that extends the full width of the door and releases on contact anywhere along its length.

Each release type is tested to a force threshold, usually between five and fifteen kilograms applied perpendicular to the bar. The mechanism inside the device translates that horizontal push into a vertical or lateral movement that withdraws the latch bolt from the door frame. A well-maintained panic bar operates in a single fluid motion, with no separate twist, pull or second step required.

Match the grade to occupancy and risk

Panic hardware is manufactured to EN 1125, the European standard that defines performance under emergency conditions. Buildings are classified by use, and each classification determines the minimum grade of panic device you fit. Grade 3 suits low-traffic environments such as small offices or storage areas where fewer than fifty people work. Grade 4 covers medium occupancy – schools, shops, workshops – where crowds gather but movement is predictable. Grade 7 is specified for high-occupancy or high-risk buildings: theatres, concert halls, sports venues, hospitals and multi-storey car parks.

The grade reflects cycle testing, corrosion resistance and force tolerance under repeated use. A Grade 7 device is tested to two hundred thousand operating cycles and must continue to function after exposure to salt spray and temperature extremes. Fitting a lower grade than your building requires is a breach of fire safety regulations and can void your insurance.

Check the fire rating of the door and the bar together

A panic bar must be certified alongside the door it is fitted to. An Fred Duncombe fire door with an FD30 rating – thirty minutes of fire resistance – needs hardware that has been tested on a door of that specification. The bar, the latch, the frame strike and any overhead closer are all part of the certified assembly. Swapping one component for an untested alternative breaks the certification, even if both parts carry a CE mark on their own.

Manufacturers publish compatibility lists showing which panic devices work with which door blanks and frame types. When you order a panic bar, the supplier should ask for the door manufacturer, the fire rating and the frame material. If they do not, you are responsible for checking the combination yourself before installation.

Know when regulations make a panic bar compulsory

UK building regulations and fire safety guidance – primarily Approved Document B and the Regulatory Reform (Fire Safety) Order – set out where panic hardware must be fitted. The requirement is triggered by a combination of occupancy, building use and the number of people who may need to use the exit at once.

  1. Establish the maximum occupancy of the room or floor the door serves, including staff, visitors and contractors who may be present at peak times.
  2. Identify whether the building is classed as an assembly space, a place of public resort, a licensed premises or a workplace with shift patterns that could put more than sixty people through a single exit route.
  3. Confirm that the door in question is part of a designated fire escape route, not a secondary exit or a door used only for deliveries.
  4. Check the local fire risk assessment, which may impose stricter requirements than the minimum guidance if the building has a history of incidents, holds vulnerable occupants or stores hazardous materials.

As a rule, any door serving more than sixty people in an area of public access needs panic hardware. Schools, cinemas, leisure centres, nightclubs, hotels and retail premises above a certain floor area all fall into this category. Offices with open-plan floors exceeding one hundred occupants often require panic bars on at least two escape routes, even if individual departments are smaller.

Distinguish between panic and emergency exit hardware

You will also encounter emergency exit hardware, certified to EN 179 instead of EN 1125. Emergency exit devices are intended for doors used by people familiar with the building – staff, regular contractors – and they permit a two-stage release: you may need to lift a lever handle as well as push a pad. Panic hardware, by contrast, is specified where the public or people unfamiliar with the layout must be able to exit immediately, without instruction or prior knowledge.

The practical difference is speed and simplicity. If your building receives visitors, guests, customers or pupils, fit panic hardware. If the door is in a back-of-house area accessed only by trained staff, emergency exit hardware may suffice, but the fire risk assessment has the final say.

Plan the installation with frame preparation in mind

A panic bar is only as reliable as the frame it latches into. The strike plate must be morticed into a steel or hardwood frame at the correct height, and the recess must be deep enough to accept the full length of the latch bolt without bottoming out. Timber frames in older buildings often lack the depth or strength to hold a modern panic device under repeated use, and you may need to fit a reinforcing plate or replace the frame section entirely.

Check the backset – the distance from the door edge to the centre of the spindle – before ordering. Standard backsets are either sixty millimetres or seventy millimetres, but bespoke doors and imported hardware can differ. Measure twice; a mismatch means the latch will not align with the strike, and the door will either fail to close or jam shut.

Pair the panic bar with a suitable closer

Fire exit doors must be self-closing, so every panic bar installation includes an overhead or concealed door closer. The closer's power rating – usually size three, four or five – must be sufficient to overcome the door's weight and any wind pressure on the external face, whilst still allowing the panic bar to release at the certified force threshold. An underpowered closer leaves the door ajar; an overpowered one makes the bar too stiff to operate safely.

For more on selecting and adjusting door closers in fire-rated applications, see our guide on stopping a fire door slamming, which covers the four adjustments you can make without compromising the closer's hold-open or closing speed.

Maintain the device with monthly pressure tests

Panic hardware is mechanical, and moving parts wear. Monthly checks catch problems before they become dangerous. Push the bar firmly from one end, then the centre, then the other end; the latch should withdraw cleanly each time with no sticking, grinding or excessive play. Inspect the fixing screws on the inside face – they work loose under vibration – and check that no paint or adhesive has entered the mechanism from recent redecoration.

Once a year, remove the cover plate and clean the internal linkage with a dry brush. Do not oil the mechanism unless the manufacturer's instructions permit it; some modern panic bars use nylon bushes that swell when exposed to lubricant, causing the bar to seize. Replace any bent or cracked components immediately; a panic bar that looks serviceable but has a fractured internal arm will fail under load, trapping occupants inside.

Test the bar under simulated emergency conditions

A panic bar must work when pushed by someone moving fast, in low light, possibly whilst carrying a child or bag. Simulate that scenario: have a colleague approach the door at walking pace without slowing, push the bar with their forearm rather than their hand, and confirm that the door opens without resistance. If the tester has to adjust their grip, aim for the centre or push a second time, the device is not meeting its design brief.

Where the door opens onto a landing or stairwell, check that the swing does not obstruct the route or strike the opposite wall. Approved Document B requires a clear width of at least one metre in the direction of escape, measured when the door is fully open.

Compare panic bar types by application

Type Release action Typical use EN standard
Push-pad panic bar Downward pressure on wide pad Offices, schools, retail EN 1125
Touch bar (crash bar) Contact anywhere along rail Theatres, stadiums, nightclubs EN 1125
Emergency exit device Lever lift and push Staff-only areas, workshops EN 179
Vertical rod panic exit Push bar drives rods top and bottom Double doors, tall openings EN 1125

Source the right device for double doors and tall frames

Vertical rod panic exits are fitted where the door has no frame at the top or bottom – typically on double doors where one leaf is held by floor and head bolts rather than a central mullion. Pushing the horizontal bar drives vertical rods that withdraw into pockets at the top and bottom of the door, releasing the leaf in one action. This configuration is common in sports halls, assembly rooms and warehouse loading areas.

Tall doors – anything over two and a half metres – may need a panic bar positioned higher than the standard one-metre height to ensure the mechanism can be reached by someone of shorter stature or a child. The positioning must still comply with the force and accessibility requirements of EN 1125, so measure carefully and consult the manufacturer's specification sheet before drilling.

Understand outside access and key override

Panic bars are designed for one-way exit. Outside access is controlled separately, either by a thumb turn lock visible from inside, a keyed cylinder on the external face, or an intercom and electric strike release. Combining a panic bar with external access means the door must fail safe – it must always allow exit from inside, even if the key cylinder is removed or the electric strike loses power.

Some panic devices include a mechanical dogging feature that holds the latch withdrawn, converting the door into a free-swing opening during low-occupancy hours. Dogging is not permitted on fire exit doors during any period when the building is occupied, and most fire risk assessments prohibit it entirely. If you need to hold a fire exit open for ventilation or access, fit an electromagnetic door holder wired to the fire alarm, which releases the door automatically when smoke is detected.

Recognise when replacement becomes necessary

Panic bars have a finite service life. High-traffic doors in schools, hospitals and shopping centres may reach their tested cycle count within five to eight years, whilst bars in low-use buildings can last twenty years or more. Visible signs of wear include a loose bar that rattles when the door is closed, a latch that does not fully retract, screw holes that have elongated or stripped, and surface corrosion that has spread beneath the finish.

If the door has been forced open – common after hours when staff have forgotten keys – inspect the internal linkage for bent arms or cracked mounting plates. A forced door often leaves the panic bar appearing intact from outside whilst the mechanism inside has fractured, and the next person to rely on it in an emergency will find it jammed.

Replacement panic bars must match the original certification. Keep a record of the make, model and grade of every panic device in your building, along with the fire door schedule that lists which doors are rated and to what standard. For guidance on selecting compliant hardware across a range of fire door applications, read our article on choosing handles for a fire door, which covers the four criteria you check first.

#Panic hardware #Fire exit

Download PDF: Panic bar inspection checklist PDF, 29 KB

Further reading

  1. Fire dooren.wikipedia.org
  2. Panic and emergency exit hardware | ASSA ABLOYassaabloy.com

Frequently asked questions

How much force should it take to open a panic bar?

A panic bar certified to EN 1125 must release with a maximum force of fifteen kilograms applied perpendicular to the bar. Most devices are set to operate at between five and ten kilograms, allowing even a child or someone with limited strength to push the door open in an emergency.

Can you fit a panic bar to any fire door?

Only if the panic bar has been tested and certified with that specific door and frame assembly. The door manufacturer's fire certificate will list compatible panic hardware by make and model. Fitting an untested combination voids the fire rating.

What is the difference between a panic bar and a crash bar?

The terms are often used interchangeably, but technically a crash bar describes a full-width horizontal rail that releases on contact anywhere along its length, whilst panic bar is the broader term covering push-pad and touch-bar devices as well. Both must meet EN 1125 when used in public buildings.